The summarizer is used for a device for which collecting multiple data points throughout the course of an encounter window is needed.
- Ex: A participant is asked to check their glucose level 4x/day in order to be be marked as compliant
Setup
- Source: The device that the summarizer is gathering data from
- Selection Field: The field on the source device that the summarizer is looking at
- Min Acceptable value: the minimum value that a value needs to be in order for it to be considered . Any value lower than this will be considered invalid. If left null there will be no minimum for a value to be valid.
- Max Acceptable value: the maximum value that a value needs to be in order for it to be considered valid. Any value greater than this will be considered invalid. If left null there will be no maximum for a value to be valid.
- Separation rule: the minimum amount of time in hours between each data point for it to be considered valid.
- Note: If both min and max acceptable values are null, then any value will be considered acceptable
total_value_count: the total number of values that have been summarized
invalid_below_count: the number of values that fell below the min acceptable value
invalid_above_count: the number of values that were above the max acceptable value
- valid_separated_count: the number of values that met the separation rule
values: A string of comma separated 'value - date' pairs
- valid_value_count: the number of values the were above the min acceptable values and also below the max acceptable value
Notes: