Initial Integration Set-Up
...
- An extra menu item should now show up under Manage Study: Epic Flowsheet Mapping
- Navigate into EPIC Flowsheet Mapping
- Create a "New EPIC Flowsheet Mapping" using the following data. In Epic, this flowsheet is: UPHS AMB WTH BLOOD PRESSURE [347]
- Device =Blood Pressure Device
- Export Tag = formatted_blood_pressure
- Flowsheet = 21000110
- Flowsheet Template ID = 21000111
- Multiplier = leave blank
- Approval Required (default is true)
- When set to true (default value) data will need to be approved from manage data before being sent to EPIC flowsheets
- When set to false data will automatically be sent to EPIC flowsheets without needing approval
- In order to prevent issues all flowsheet mappings for a given data source need to have the same value for this field
- If one mapping has a true value and another has a false the data will be sent to the flowsheet that has a false value and the form submission's epic status will be updated to sent (even though the mapping that required approval was not actually sent)
- This will cause headaches and confusion so don't do it. As discussed on the Merge Request if it becomes an issue we will address it in the future.
...
If you try to send a data point(s) to EPIC and it fails, you will receive the incident below:
Incident type: Software" and text is "EPIC FAIL: A row of data fails to submit to the epic flowsheet."